초전도 변압기용 Cryocooling System
극저온 장치 > 초전도 전력기기 > 초전도 변압기
Purpose : Test of HTS Transformer
Technical Features
– RT Bore : 334 mm
– Vacuum vessel OD : 948 mm
ID : 334 mm
Height :1200 mm
– LN2 vessel OD : 848 mm
ID : 400 mm
Height : 1050 mm
– Operating Temp : 64 ~ 67K
– Cooling Capacity : 560W @ 65K
– Cooler : 2-AL300
Code No. : M0303
Customer : Hyosung Heavy Industry
Delivery : 2003. 8. 19.